Subscribe to this Blog
Elekta Word Cloud

Biological-based planning maximizes critical organ sparing in fast VMAT for SBRT of prostate, lung and liver lesions. Med. Phys. 39, 237 (2012)

High-dose Stereotactic Body Radiation Therapy (SBRT) has emerged as a critical treatment option for patients with prostate, lung and liver cancer. The challenge has been delivering SBRT’s large doses as quickly as possible, for improved patient comfort and to reduce the chance the patient will move during treatment delivery. While Volumetric Modulated Arc Therapy (VMAT) promises much faster treatment delivery, clinicians have been reluctant to sacrifice plan quality to deliver therapy faster. The Editor Pick in the January 2012 issue of Medical Physics is an article by Quentin Diot, Brian Kavanagh, Robert Timmerman, and Moyed Miften that demonstrates that the use of Monaco biological-based planning meets the need for fast SBRT with high quality plans.

 

“We found that using biological-based optimization and VMAT we could deliver faster treatments with comparable or better plan quality for patients with prostate, lung and liver patients, compared to fixed gantry [i.e., step-and-shoot] IMRT,” says the University of Colorado School of Medicine’s Moyed Miften, Ph.D., a senior-author of the paper, Biological-based optimization and volumetric modulated arc therapy delivery for stereotactic body radiation therapy.*

 

The researchers found that biological-based planning achieves the goal of sparing organs-at-risk (OARs) – the physician’s main concern when delivering SBRT’s significantly larger radiation doses per treatment fraction. Subjects included 24 SBRT patients with prostate, liver or lung cancer.

 

Biological-based planning v. physical planning

Elekta’s Monaco® uses biological-based plan optimization, in contrast to planning systems that offer only physical planning.

 

The optimization process entails the twin goals of maximizing the dose to the target and minimizing the dose to OARs. Because targets and OARs are contiguous, these goals compete and the optimizer needs to make the appropriate trade-offs.

 

With physical-based optimization, the planner manually enters points (volume receiving a given dose or dose volume (DV)) to constrain the optimization based on available clinical data that demonstrate a correlation between tumor control and normal tissue complications and particular DV metrics.

 

“These metrics are only surrogates of the biological response and different plans that meet the same discrete constraints can have a very different biological outcome,” explains Quentin Diot, Ph.D., of the University of Colorado School of Medicine. “Conversely, biological-based optimization – such as that provided by Monaco – uses model functions directly related to biological outcomes to guide the optimization, and can distinguish between apparently equivalent physical plans.”

 

Read more at: http://www.elekta.com/press/4c3c9876-cbb8-420d-968e-5bfd46cc413a/medical-physics-pick-paper-shows-elekta-s-monaco-enables-vmat-delivery-of-sbrt-without-sacrificing-plan-quality.html.

 

*Biological-based optimization and volumetric modulated arc therapy delivery for stereotactic body radiation therapy. Med. Phys. 39(1), January 2012.

 

Did you like this? Share it:

Leave a Reply

*

  • Leksell Gamma Knife Perfexion Advanced Program for Stereotactic Radiosurgery September 8, 2015
      Objective To further enhance the participant’s knowledge of Leksell Gamma Knife Perfexion and its advanced applications in the field of stereotactic radiosurgery. Specific focus will be placed on Gamma Knife surgery with or without the Extend System for several different indications. Patient selection, radiosurgical techniques and complication avoidance as […]
  • Leksell Gamma Knife Perfexion - Upgrade Program December 10, 2013
    Objective To receive aspects of clinical and technical training for handling new features of Leksell Gamma Knife Perfexion, when upgrading from previous models. Training on the dynamic workflow of Leksell GammaPlan includes instruction on using the pre-planning and follow-up features of the program as well as on developing treatment plans using composite sho […]
  • Leksell Gamma Knife Perfexion - Introductory Program December 8, 2013
    Objective To identify the basic principles and biophysics of Gamma Knife surgery and how they apply to day-to-day patient treatment. Review the clinical indications, parameters of treatment and outcomes of Gamma Knife surgery. Recognize radiation safety issues and principles, as well as become familiar with emergency procedures that pertain to Leksell Gamma […]
  • Leksell Gamma Knife Perfexion - Applications Introductory Program November 17, 2013
    Objective To make users confident in the operation, care and maintenance of Leksell Gamma Knife Perfexion. The course focuses on radiation physics, dosimetry, stereotaxy for Gamma Knife surgery, quality assurance (QA), technical information and treatment planning using Leksell GammaPlan®.   Content ■      Principles of stereotaxy and radiosurgery ■      Prin […]
  • Leksell Gamma Knife Perfexion / 4C - Introductory Program November 10, 2013
    Objective To obtain knowledge about the practical aspects of stereotactic radiosurgery using Leksell Gamma Knife. Principles of radiation physics and radiobiology, that apply to single-session, focused, small volume irradiation will be covered. Registrants should be able to create radiosurgery dose plans for various indications.   Content ■      Principles a […]
  • Leksell Gamma Knife Perfexion Clinical Introductory Program October 6, 2013
    Objective To introduce clinicians to Gamma Knife® surgery with Leksell Gamma Knife Perfexion and Extend™ System. The course focuses on clinical information, combined with hands-on sessions using Leksell GammaPlan®. Experts with years of experience from Gamma Knife surgery are selected to lecture on this course. Training center and duration 4-day course at Un […]
  • XiO - Application December 16, 2012
     OBJECTIVE To provide applications training in the use of XiO for treatment planning. The course provides an understanding of the software enabling the user to efficiently create effective treatment plans using our product. COURSE CONTENT Structure Contouring Digitized Contour-based Planning 2D Irregular Field Planning 3D External Beam Planning Special Plann […]
  • XiO IMRT December 9, 2012
    Objective To provide applications training in IMRT treatment planning utilizing the Xio Treatment Planning System. The course provides an understanding of the IMRT software enabling the user to efficiently create effective IMRT treatment plans using our product.   Course Content Contouring for IMRT Planning Beam Placement IMRT Prescription Optimization Segme […]
  • SRT December 9, 2012
    OBJECTIVE   This advanced clinical training program is designed to present the processes required to implement SRT for routine treatment on Elekta Axesse™ and other Elekta linear accelerators sterotactic capabilities.   COURSE CONTENT • Recognize indications for and outcomes of SRT/Radiosurgery • Understand dose selection, fractionation and planning techniqu […]
  • Monaco December 9, 2012
    OBJECTIVE  To provide applications training in advanced radiobiology-based IMRT treatment planning.  The course provides an understanding of the IMRT software enabling the user to efficiently create effective IMRT treatment plans using our product. COURSE CONTENT Contouring / Image Fusion for IMRT Planning Beam Template Creation The IMRT Prescription IMRT Co […]