Subscribe to this Blog
Elekta Word Cloud

 

Symmetry helps radiation oncologists at Riverside & University of Virginia Radiosurgery Center avoid excess dose to healthy tissues by isolating mobile tumors

In treatments of only the first handful of patients with lung or liver tumors, Riverside & University of Virginia Radiosurgery Center (Newport News, Va.) clinicians have demonstrated the dramatic benefit that Elekta’s Symmetry™ 4D image guidance technology can provide for patients whose tumors move with their breathing. Symmetry essentially yields a more distinct picture of the tumor, without the blurring associated with breathing motion.

 

By having a clearer picture of the tumor position and its motion, physicians have been able to improve their targeting of tumors, thereby avoiding having to treat a larger margin of healthy tissue around the lesion. A Symmetry scan is acquired just before treatment to ensure that the patient is correctly positioned, and to visualize tumor movement.

 

“Symmetry scans give us clearer information about the movement of the tumor, allowing us to increase the safety of treating our patients by decreasing the dose to healthy tissues, while hopefully providing a better clinical outcome,” according to Riverside medical physicist Kelly Spencer.

 

Tumor motion in sharper focus

Before they began using the Symmetry feature in Elekta’s XVI package of IGRT tools, Riverside clinicians were using sophisticated XVI 3D cone beam CT (VolumeView™ CBCT) imaging technology integrated with their Elekta Synergy® S to image tumors. These pre-treatment scans provide physicians with added confidence in the margins that they have planned. Although seeing a target with IGRT technology such as VolumeView has been a key clinical improvement, the motion still created a blur that encompassed the tumor’s range of motion.

 

“For our current protocol, we would create an ITV [internal target volume] to cover the blur we see on the VolumeView,” Spencer says. “We began using Symmetry on a couple of patients with lower lung lesions near the diaphragm where we would expect tumor motion to be an issue. We were actually quite mesmerized by the images Symmetry provided. We could clearly see the actual motion of the delineated tumor with respect to the patient’s breathing.”

 

The same Symmetry benefit applied to a recent patient with a liver tumor situated near the diaphragm. In this case, clinicians inferred tumor motion by observing the movement of the liver with the patient’s breathing.

 

“We wanted to use Symmetry to see how the superior border of the liver moved, and what we observed was that it did not move simply superior to inferior – there was almost a rolling pattern to the liver motion,” Spencer recalls. “We knew that the liver didn’t necessarily move symmetrically on CBCT scans, but it was harder to appreciate due to motion artifact. This movement probably varies between patients, so that is an excellent reason to use Symmetry to evaluate this motion on a case-by-case basis.”

 

Read more at: http://www.elekta.com/press/353b6d89-353e-405c-a736-78b0d5b9d886/virginia-physicians-use-elekta-software-to-better-target-moving-tumors-in-patients-with-lung-or-liver-cancer.html.

 

*Approval of indications may vary between different countries. Additional regulatory clearances may be required in some markets.

Did you like this? Share it:

Leave a Reply

*

  • Leksell Gamma Knife Perfexion Advanced Program for Stereotactic Radiosurgery September 8, 2015
      Objective To further enhance the participant’s knowledge of Leksell Gamma Knife Perfexion and its advanced applications in the field of stereotactic radiosurgery. Specific focus will be placed on Gamma Knife surgery with or without the Extend System for several different indications. Patient selection, radiosurgical techniques and complication avoidance as […]
  • Leksell Gamma Knife Perfexion - Upgrade Program December 10, 2013
    Objective To receive aspects of clinical and technical training for handling new features of Leksell Gamma Knife Perfexion, when upgrading from previous models. Training on the dynamic workflow of Leksell GammaPlan includes instruction on using the pre-planning and follow-up features of the program as well as on developing treatment plans using composite sho […]
  • Leksell Gamma Knife Perfexion - Introductory Program December 8, 2013
    Objective To identify the basic principles and biophysics of Gamma Knife surgery and how they apply to day-to-day patient treatment. Review the clinical indications, parameters of treatment and outcomes of Gamma Knife surgery. Recognize radiation safety issues and principles, as well as become familiar with emergency procedures that pertain to Leksell Gamma […]
  • Leksell Gamma Knife Perfexion - Applications Introductory Program November 17, 2013
    Objective To make users confident in the operation, care and maintenance of Leksell Gamma Knife Perfexion. The course focuses on radiation physics, dosimetry, stereotaxy for Gamma Knife surgery, quality assurance (QA), technical information and treatment planning using Leksell GammaPlan®.   Content ■      Principles of stereotaxy and radiosurgery ■      Prin […]
  • Leksell Gamma Knife Perfexion / 4C - Introductory Program November 10, 2013
    Objective To obtain knowledge about the practical aspects of stereotactic radiosurgery using Leksell Gamma Knife. Principles of radiation physics and radiobiology, that apply to single-session, focused, small volume irradiation will be covered. Registrants should be able to create radiosurgery dose plans for various indications.   Content ■      Principles a […]
  • Leksell Gamma Knife Perfexion Clinical Introductory Program October 6, 2013
    Objective To introduce clinicians to Gamma Knife® surgery with Leksell Gamma Knife Perfexion and Extend™ System. The course focuses on clinical information, combined with hands-on sessions using Leksell GammaPlan®. Experts with years of experience from Gamma Knife surgery are selected to lecture on this course. Training center and duration 4-day course at Un […]
  • XiO - Application December 16, 2012
     OBJECTIVE To provide applications training in the use of XiO for treatment planning. The course provides an understanding of the software enabling the user to efficiently create effective treatment plans using our product. COURSE CONTENT Structure Contouring Digitized Contour-based Planning 2D Irregular Field Planning 3D External Beam Planning Special Plann […]
  • XiO IMRT December 9, 2012
    Objective To provide applications training in IMRT treatment planning utilizing the Xio Treatment Planning System. The course provides an understanding of the IMRT software enabling the user to efficiently create effective IMRT treatment plans using our product.   Course Content Contouring for IMRT Planning Beam Placement IMRT Prescription Optimization Segme […]
  • SRT December 9, 2012
    OBJECTIVE   This advanced clinical training program is designed to present the processes required to implement SRT for routine treatment on Elekta Axesse™ and other Elekta linear accelerators sterotactic capabilities.   COURSE CONTENT • Recognize indications for and outcomes of SRT/Radiosurgery • Understand dose selection, fractionation and planning techniqu […]
  • Monaco December 9, 2012
    OBJECTIVE  To provide applications training in advanced radiobiology-based IMRT treatment planning.  The course provides an understanding of the IMRT software enabling the user to efficiently create effective IMRT treatment plans using our product. COURSE CONTENT Contouring / Image Fusion for IMRT Planning Beam Template Creation The IMRT Prescription IMRT Co […]